com.ampworth/calculators·Utilities

Ampworth calculators

UK solar PV and heat pump calculators that follow the published MCS methods. Open, no key.

Stars
—
Version
1.0.20261016
License
—
Review
Passed
Registry update
Oct 16, 2026

Connect

remote
Terminal
$claude mcp add --transport http calculators https://ampworth.com/mcp/calculators

Headers

Nothing to configure — it works as is.

Security review

Review passed

Reviewed 5m ago.

tools
12 tools scanned
metadata
scanned

No findings.

Tools

12
  • connection_route

    Work out which ENA connection procedure a domestic installation of solar panels, batteries or both falls under: connect first and notify the distribution network operator within 28 days, or apply and wait for approval before anything is connected. The rules are the ENA's engineering recommendations, not MCS documents: EREC G98 for small installations, EREC G99 for everything larger, and EREC G100 for export limitation. Every test is in amps per phase at a nominal 230 V, and it applies to the premises as a whole, so list EVERY inverter that can export, existing ones included. A battery counts as generation even if it only ever charges from the panels. The figure that counts is each inverter's registered capacity: its AC rating, or a lower limit the manufacturer has fixed. It is NOT the panels' kWp. A 4.4 kWp array on a 3.68 kW inverter is a 3.68 kW installation. Where an inverter has been capped below its hardware rating, give the hardware rating as 'designCapacityKw', because G99 tes

  • heat_pump_noise

    Calculate the sound pressure level an air source heat pump produces at an assessment position, and whether it meets the 37 dB(A) permitted development noise limit, using the method in MCS 020. The formula is Lp = Lw + 10 log(Q / 4.pi.r^2) - Ab. Lw is the A-weighted sound POWER level of the unit from its product fiche, energy label or the MCS product database. This is not the sound pressure level, which is a smaller number that already has a distance built into it; confusing the two produces an answer that is wrong by about twenty decibels. The figure for low noise mode must not be used. Q is the directivity factor, from the count of reflecting surfaces within one metre of the unit that extend at least a metre past it in two or more directions. The ground counts; vegetation does not. One surface gives Q=2, two gives Q=4, three gives Q=8. More than three cannot meet MCS 020 at all. r is the straight-line distance in metres to the assessment position, which is a window or door of a ha

  • heat_pump_running_cost

    Compare what a household spends heating on its current fuel with what the same heat would cost from a heat pump. The heat demand is worked out from the household's own metered fuel use, not from a model, because a year of bills describes a particular house far better than any estimate of it. Supply the annual fuel use in the fuel's own unit (kWh for gas and electricity, litres for oil and LPG, kilograms for coal), its price per unit in pounds, and the seasonal efficiency of the existing appliance, which defaults to a realistic figure for that fuel instead of the one on the badge. The comparison turns on one ratio. A heat pump costs less to run whenever its seasonal coefficient of performance beats the ratio between the price of a unit of electricity and the price of a unit of heat from the current fuel. The result reports that break-even figure explicitly. SCOP must be the figure at the flow temperature the system is actually designed for. The same machine can return 4.2 at 35 degre

  • heat_pump_size

    Estimate the heat pump a UK house needs, and what it would cost to run against the fuel it burns now. IMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation to BS EN 12831, and nothing here replaces that. Say so whenever you report a result from this, and point the user at the room-by-room calculation. What the figure is for is checking whether a size somebody has been quoted is plausible, because oversizing is the commonest fault in heat pump installations and it is invisible to the person living with it. There are two routes and the first is much the better one. From metered fuel, which is preferred: give 'annualFuelUse' from a year of bills. The fuel becomes heat delivered, hot water comes off it using the MIS 3005-D formula, and what remains divided by the local heating degree days gives the building's heat loss coefficient in watts per kelvin. Degree days are computed from the Met Office monthly means published in MGD 007 section 5. Fr

  • hot_water_cylinder

    Work out the daily hot water demand of a dwelling and the size of cylinder a heat pump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007. The demand is 45 litres a day for each of N, where N is the greater of the number of bedrooms plus one and the number of people actually living there. For a new build, where occupancy is unknown, the bedroom count is used. The cylinder does not have to hold a whole day's demand, because it reheats as it empties. What it must cover is the largest draw-off before the heat pump catches up, which is why a larger heat pump needs a smaller cylinder: reheat time is volume times temperature rise, divided by 14.3 times the kW. The result gives the BS 6700 minimum, a recommended size rounded to a volume cylinders are made in, and the reheat time. Note that cylinder volume is not the whole story: a heat pump cylinder needs a much larger coil than a boiler cylinder, because the water arrives cooler and there is less t

  • list_calculators

    Lists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to build a valid request: the compass directions and their orientations, the shading descriptions, the twenty-five solar postcode zones, the eight heat pump design locations with their design temperatures, the room types and their internal design temperatures, the heat loss element kinds, the occupancy archetypes and the fuel types. Call this when a value must be one of a fixed set and you are not sure what the set is.

  • radiator_flow_temperature

    Work out the flow temperature a heat pump must produce to heat a room through a given radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007. This is the calculation that decides whether a heat pump will be cheap or expensive to run. A heat pump's efficiency falls as the water temperature rises, by roughly two to three per cent per degree, and the temperature it must produce is set by the radiators, not by the machine. Supply the room's design heat loss in watts, from a room-by-room calculation, and the rated output of the radiator in that room. British catalogues normally quote at a mean-water-to-air difference of 50 K; if yours quotes 60, say so and the figure is restated. The result gives the oversize factor, which is the radiator's output at 50 K divided by the room's heat loss, and converts it to a required flow temperature through the BS EN 442 output law. Star ratings run from 0 to 6, one star per five degrees of flow temperature, with

  • room_heat_loss

    Calculate the design heat loss of a single room in watts, following BS EN 12831 as MIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in that room must be able to deliver. BS EN 12831 is a room-by-room method. Run this once for each heated room and add the results; sizing a heat pump from floor area alone is what produces the oversized installations that cycle all winter. Internal design temperatures come from Table 1 of MIS 3005-D and follow from the room type: 22 for a bathroom, 21 for living and dining rooms, 18 for bedrooms, halls, kitchens and toilets. These are minimums, so a higher figure is accepted and a lower one is refused. External design temperatures come from Table 2, for eight locations, in two columns: 'a' is the 99% figure and 'b' the colder 99.6% one, which needs no uplift for intermittent heating. Each element needs an area, a U-value, and a kind. The kind matters because it fixes which temperature difference applies.

  • solar_pv_output

    Estimate the annual AC electricity output of a UK solar photovoltaic system, in kWh, using the standard estimation method that MIS 3002 requires every MCS certified installer to use. The method is: annual output = kWp x Kk x SF, where Kk is read from the MCS irradiance dataset for the site's postcode zone, roof pitch and orientation, and SF is a shade factor between 0 and 1. Supply the postcode and the array's capacity in kWp, plus the roof's pitch in degrees from horizontal and its orientation in degrees away from due south in either direction, so that south is 0, south-east and south-west are both 45, east and west are both 90, and north is 180. The result carries the tabulated yield, the estimate, and what the same array would produce at the best pitch and orientation for that zone, so a roof that is merely good is not mistaken for a poor one. This covers the United Kingdom only; the dataset has no values for anywhere else. Method from MIS 3002. These calculators follow the publ

  • solar_pv_self_consumption

    Estimate what proportion of a domestic solar PV system's annual output is consumed in the house and what proportion is exported, using the lookup tables in MGD 003. The tables are not a model. They come from half-hourly monitoring of real British households by Loughborough University, with battery behaviour modelled on top, so they carry the real shape of domestic demand: a peak before the sun is up, another after it has gone, and a quiet middle of the day. Three things index them. The annual generation, which comes from the MIS 3002 output estimate. The household's annual consumption from a bill based on actual meter readings, which defaults to the British average of 3,500 kWh where it is unknown. And the weekday occupancy pattern, which is 'home_all_day', 'in_half_the_day' or 'out_all_day'; where the pattern is unknown MGD 003 says to use the middle one, and that is what an omitted value resolves to. Battery capacity is the USABLE capacity, which is smaller than the figure printed

  • solar_pv_shading

    Convert a completed MCS sunpath shading assessment into a shade factor, using the procedure in MGD 005. The MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's useful irradiance. An assessor stands at the middle of where the array will go, plots what blocks the horizon onto the chart, and counts the segments covered. This tool takes that count and returns 1 minus the loss, which is the SF term in the MIS 3002 output estimate. Objects within ten metres of the array are near shading and are assessed separately, from each affected part of the array, not from its middle. They can be listed here for the record, but MGD 005 is explicit that near shading has a considerable effect and should be avoided. This tool does not perform the assessment. It does the arithmetic on an assessment somebody made. Method from MGD 005. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still

  • solar_pv_system_size

    Work out the solar PV system a UK home needs: the capacity in kWp, the number of panels, the battery to go with it, and what it would do to the electricity bill. This runs the MCS arithmetic backwards. The other solar calculators here each answer one question about a system somebody has already specified. This one starts from what a household uses and arrives at the system that covers it, which is the question a householder actually has. The chain is short and every link is published. Annual consumption sets the generation the array has to make. The MCS irradiance dataset behind MIS 3002 says what one kWp makes on that roof, which gives a capacity. Capacity divided by panel size gives a panel count, rounded up, because panels come whole. The MGD 003 tables then say how much of that generation the household will use and how much it will export. Only the postcode and the roof direction are required. Direction is a compass point, not an angle: 'S', 'SE', 'SW', 'E', 'W', 'NE', 'NW' or '